Safety net impact penetration tester operation method
Article from the Technical Department of Qingdao Zhongbang Instrument Co., Ltd.
Safety net impact penetration test machine preparation before test
1. Put the test bench and control box in place, and connect the power supply of the electrical box and the power supply of the electric hoist.
2. Prepare test samples and place them in accordance with the standard requirements.
Safety net impact penetration tester operation steps
Safety net impact test:
1. Connect the electrical control box to the power supply.
Through the up and down buttons on the panel, the electromagnetic release device is lowered to the bottom, press the "release" to hang the test ball, press the "pull" lock, then press and hold the "up" button to lift, for safety reasons , Do not be too high, and follow-up operations do not stand under the test ball.
2. Place the sample in place:
The sample is tied around the (6m*3m) frame of the lower shelf by means of a tether around the sample. Note that when tethering, each tether should be stressed as evenly as possible.
3. Adjust the position of the test ball to the zero point of the test on the test network. Press the ↠on the height meter and the height is zero. When the test ball reaches the set test height, the rise is automatically stopped.
(Test ball height setting method: Press and hold to release P1, press to enter the parameter setting state, for example, 01.200 is the height of 1.2 meters when prompted. Use the key to adjust and set the test height. Press to store the set parameters. Press until returning to measurement state. Please set other parameters when changing this parameter!!!)
(In the same way, the Fi parameter can be fine-tuned so that the instrument's display value corresponds to the actual boost value!)
4. Press the "Release" button and the test ball falls instantly. A test is completed;
Observe the sample and record the result;
If you continue testing, repeat the above steps. If it is not necessary, turn off the power supply and make rain and protective measures for the corresponding devices.
Safety net penetration test:
1. Lower the electromagnetic release part by the electric hoist to a place where the test stick can be conveniently placed.
2. Use the electromagnetic release part to hang the test rod through the wire rope, and then press the “suction†button to pull the test rod. Then, the electromagnet release part along with the test rod will rise to the height of 1m from the center of the net through the electric hoist.
3. Click on the "Release" button and the test stick will fall freely in a free fall.
Check the condition of the tested sample, record the test result, and complete one test.
Safety Net Impact Penetration Tester Operation Precautions
1, the release device, power release, power off, is strictly prohibited for a long time in the release state!
2. Pay attention to rain and snow protection of all devices, especially electrical parts.
3, test bench must be fixed firmly, test ball must be arranged below a soft sand test pit.
4. For the sake of safety, the test ball is lifted and the operator is prohibited from standing under the test ball. It is forbidden to reach under the test stick during the test!
5. During the test, please don't let busy people wait and watch around the test stand.
This article is an article of Qingdao Zhongbang Instrument Co., Ltd. If you need to reprint it, be sure to add the source of the description. Reproduce the misappropriation without permission.
Commercial Grow Light
Ultra Plantâ„¢ Grow Light offers One Chip Technology aimed to meet your indoor growing expectation such as improve plants' quality, increase yield, or better the margin, etc., all for helping you realize a higher return on your crops.
Ultra Plantâ„¢ Grow Light is combined our advanced All-In-One technology with patented optical design and customized light full spectrum supported from our experienced LED engineers, plant specialists and other partners working on horticulture.
From Ultra Plantâ„¢ APP, you are able to schedule the growing process including photoperiod, brightness and spectral in advance. The lighting system will help you grow smarter, easier and better.
Ultra Plantâ„¢ is the most versatile horticultural grow lighting fixture for indoor plants with flexible full spectrum, brightness control and uniform, wider light distribution, suitable for top lighting of all types of crops. No matter it applies to anywhere for any crop, Ultra Plantâ„¢ can do perfect work for you.