1. Please confirm the power and power marked on the motor of this system and select the appropriate wire.
2. Please confirm whether the pure and wastewater takeover is correct.
3. Determine the wire diameter of the main power supply program line and whether there is a leakage switch.
4. The line reserved for the liquid level switch or high voltage controller next to the automatic flush timer cannot be used as the power input.
5, please install automatic water softener, installed when the backwash RO host will stop the rotation of the device, so as not to let RO inhale salt water.
6. Please confirm whether the IN or OUT caliber is correct in the automatic water softener process.
7. Before the soft water machine is installed, the pressure pump must be filled with a full-water stop device to prevent the motor from being burned out due to no-load operation of the water pump.
8. Please clean the pre-pretreatment equipment every day <quartz sand filter and activated carbon filter> to maintain adequate supply of main engine water.
9. If the equipment is equipped with a UV germicidal lamp, please adjust the power supply and do not make the power supply jump to prevent the lamp tube from being burned out.
10. If the pretreatment adopts anti-scale and dosing method instead of softening, it is recommended that the user should manage the pure water equipment by hand and pay attention to the use of anti-fouling agent. The anti-scaling agent of the chemical kit should always be added.
Suggestions
1, when installing this system, it is best to install multi-media filter, automatic water softener or scale inhibitor to protect the RO membrane.
2. The automatic softener must pay attention to the addition of coarse salt for resin regeneration.
3. If the automatic water softener is not installed, the ratio of pure water and waste water should be lowered depending on the quality of raw water.
4. If the raw water inlet pressure gauge does not reach 2.0kg/cm2 or more, install a pressure pump at the front of the system.
5, the machine factory reserved for the empty wiring next to the automatic flush timer for the liquid level control line, apply pressure switch and floating ball level controller, please choose a kind of installation.
7. Please purchase the softening water reagent produced by our company to check the water quality of the resin softened and discharged. phone.
8. When the amount of pure water produced is reduced by more than 10%, the salt content of the produced water increases, and when the pressure difference between the two ends of the membrane is higher than 15 PSI, a professional should clean the RO membrane.
Precautions