Fleixble Diamond Loop and Endless Wire Saw Diamond wire Loop with diamond wire saw is one of the flexibility cutting tool, setting the diamond crystals onto the steel surface and making one-way movement, mainly used for hard and brittle materials cutting, such as: sapphire, special ceramic materials , marble, tyre, rubber, stone, monocrystaline silicon, and polycrystalline silicon, etc.The flexible CBN and Diamond Wire from HANS will win you over with their high tensile strength, their strong grain bonding as well as the high quality of the diamond loop wire and the diamond grain. Diamond Loop/Endless Foam Wire Saw is one of the most flexible cutting tools, which can set on teh surface of diamond crystals. While cutting, the diamond wire will move from one direction with the speed from 30-60 m/s. It will give users the great advantages. Specification Outside Diameter 0.5-1.0mm is Continue Rim Outside Diameter 1.0-1.5mm can Continue Rim or Segment Rim Outside Diameter 1.5-3.0mm is Segment Rim High efficiency on cutting, while the speed from 30 to 60 m/s Diameter from 0.3-3.0 mm,Length from 800-50000 mm and math for the popular machine in current market Cutting fits into both wet or dry environment Cutting directions could change by customer's requirement. And also could apply to cut the curved surface. Operation and Replacement of diamond wire are really convention Diamond Loop Wire Saw is one of the most flexible cutting tools, which can set on the surface of diamond crystals. While cutting, the diamond wire will move from one direction with the speed from 30-60 m/s. It will give users the great advantages. Widely used on cutting the rubber machine and hard surface of materials,such as,tire Section cutting machine,Tyre section cutting machine,artificial crystal (sapphire, silicon),Special Ceramic,Precious metal,graphite and plastic,brittle material. Also used on research field: geology,archaeology,architecture and biology etc. Also supply the diamond loop wire saw for tire section cutting machine. Compared with other diamond cutting tools, the Loop diamond wire is a flexible tool: 1)Not only can be used for straight line cutting, but also curved surface cutting; 2)Not subject to the shape of the surface of the object; 3)The workplace requires simply, but large area cutting can be carried on; 4)The use of diamond wire saw can improve resource utilization and reduce environmental pollution. Due to the above advantages, the market shares of diamond wires are getting bigger and bigger, and the scope of application is getting wider and wider. As many of our clients can testify, Hans Service and Support gives us the edge in our solutions.Whatever your requirements, We will be there for your immediate and long term needs.Professional Services & Consulting Tailored to Your Business. Excellent Products Quality; Perfect Application Solutions; Professional Technical Support; Prompt Delivery Time! diamond coated wire,diamond wire saw machine,Diamond Loop Wire Saw, Diamond Endless Wire Saw,Tire Section Cutting Diamond Wire Saw,Diamond Precision Wire Saw, Foamglass Abrasive Wire Saw, Abrasive Wire Foam Cutting,Precision Diamond Wire Saw Hans Super Abrasive Diamond Tool Co.,Ltd , https://www.hansuperabrasive.com
The correct choice of wire and cable and reasonable wiring are directly related to the fire safety of the building. Engineering applications should be strengthened in standardization and standardization. Formulate scientific and concrete plans to provide basis for wire and cable fire protection and electrical wiring of fire fighting equipment in engineering design, so that it can be safe, reliable, technologically advanced, and economically reasonable. It can effectively prevent fire caused by wire and cable and reduce the risk of fire. Casualties and property damage.
Fire prevention principle
The basic principle for the laying of fire protection on the cable line is not to extend the flame after a fire;
1 Prevent cables from catching fire.
2 Take effective fire prevention measures along the cable path or flammable zone;
3 to achieve its own flame retardant cable.
Fire prevention measures
Fire prevention measures should be taken. 1 When laying cables under the following conditions.
Super high-rise buildings should be blocked on each floor, 1 when the cable passes through different fire zones; 2 the cable is laid vertically across the floor along the shaft. Other buildings may be blocked at every 23 floors; 3 at the partitions of cable tunnels, cable trenches, and cables; 4 at fire resistance limits not less than 1h at partitions; 5 at buildings crossing partitions; , or to the channel population of the power distribution room and control room; 7 the cable leads to the openings of electrical cabinets, plates or control panels, tables;
2 Keep away from heat and fire
Cables shall not be laid; insulation shall be taken if laid in the heat pipe trenches. Electrical installations with explosion and fire hazards should not be installed; cable runs should be kept as far away as possible from steam and oil pipelines; flammable gas and flammable liquids.
3Set up fire alarm system
Select the appropriate alarm probe and alarm system suitable for the characteristics of the cable layer. At present, a wide range of linear (or cable) temperature sensitive detectors are used in cable trenches and pipeline wells; according to actual conditions.
4 High pressure water spray
It is difficult to use general fire extinguishing materials, cable corridors, and cable-intensive areas. High-pressure water spray fire extinguishing methods should be adopted. In order to make the water spray extinguishment work effectively in time, a highly sensitive monitoring and control system needs to be configured. This method is effective in large buildings and cable tunnels.
5 Strengthen cable layer (well) ventilation
As far as possible in the cable layer * external wall vents (the specific settings of the vent can be combined with a breakthrough in the fire fighting) at the same time should also establish uninterrupted power supply mechanical exhaust system, and actively use the natural ventilation conditions. In order to open the exhaust fan by automatic alarm linkage at the beginning of the fire.