Magnetic flap level gauges are usually available in the market due to their different environments and usage requirements.
normal type
Withstand the maximum working pressure: normal pressure (1.0Mpa or less)
Maximum working temperature: 80 ° C
Measuring range: 0~12m
Measuring medium density: 0.5~1.8 g/cm3
Default process connection: flange connection
Display panel installation default orientation: forward facing flange
Anti-corrosion type
Withstand maximum working pressure: 10Mpa or less
Maximum working temperature: 80 ° C
Measuring range: 0~12m
Measuring medium density: 0.5~1.8 g/cm3
Default process connection: flange connection
Display panel installation default orientation: forward facing flange
Heating type
Withstand maximum working pressure: below 10Mpa
Maximum working temperature: 200 ° C
Measuring range: 0~12m
Measuring medium density: 0.5~1.8 g/cm3
Default process connection: flange connection
Display panel installation default orientation: forward facing flange
Frostproof
Withstand maximum working pressure: below 10Mpa
Maximum working temperature: 80 ° C
Measuring range: 0~12m
Measuring medium density: 0.5~1.8 g/cm3
Default process connection: flange connection
Display panel installation default orientation: forward facing flange
High temperature type
Withstand maximum working pressure: below 10Mpa
Maximum working temperature: 200 ~ 450 ° C
Measuring range: 0~12m
Measuring medium density: 0.5~1.8 g/cm3
Default process connection: flange connection
Display panel installation default orientation: forward facing flange
High pressure type
Maximum working pressure: over 10MPa (31 MPa or less)
Maximum working temperature: 200 ° C
Measuring range: 0~6m
Measuring medium density: 0.5~1.8 g/cm3
Default process connection: flange connection
Display panel installation default orientation: forward facing flange
High temperature and high pressure type
Maximum working pressure: over 10MPa (20 MPa or less)
Maximum working temperature: 200 ~ 450 ° C
Measuring range: 0~6m
Measuring medium density:
Default process connection: flange connection
Display panel installation default orientation: forward facing flange
Explosion-proof
Withstand maximum working pressure: 10Mpa or less
Maximum working temperature: 120 ° C
Measuring range: 0~12m
Measuring medium density: 0.5~1.8 g/cm3
Default process connection: flange connection
Display panel installation default orientation: forward facing flange
Top type
Withstand the maximum working pressure: 1.6MPa
Maximum working temperature: 200 ° C
Measuring range: 0~12m
Measuring medium density: 0.5~1.8 g/cm3
Default process connection: flange connection
Display panel installation default orientation: forward facing flange
Related products: metal rotameter , magnetic flap level gauge , two-color quartz tube level gauge , plastic tube float flowmeter